Research output: Contribution to journal › Article › peer-review
Simultaneous reconstruction of emission spectra and anode current dynamics in nanosecond x-ray tubes using attenuation curves. / Paraskun, Alexandr.
In: Review of Scientific Instruments, Vol. 97, No. 11, 115201, 02.11.2026.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Simultaneous reconstruction of emission spectra and anode current dynamics in nanosecond x-ray tubes using attenuation curves
AU - Paraskun, Alexandr
N1 - Alexandr Paraskun; Simultaneous reconstruction of emission spectra and anode current dynamics in nanosecond x-ray tubes using attenuation curves. Rev. Sci. Instrum. 1 November 2026; 97 (11): 115201. https://doi.org/10.1063/5.0349535
PY - 2026/11/2
Y1 - 2026/11/2
N2 - The accurate determination of emission spectra in nanosecond pulsed x-ray tubes is critical for advanced non-destructive testing, high-speed radiography, and dosimetry calculations. In this paper, we propose a novel computational-experimental approach: the basis-pulse decomposition method with kinematic regularization. Instead of reconstructing the spectrum as a set of independent energy bins, the proposed algorithm shifts the search space into the time domain. The integral spectrum is represented as a temporal superposition of instantaneous physical basis spectra, strictly calculated using the known transient voltage waveform, Kramers' law, and models of anode self-absorption and window filtration. To stabilize the solution, we introduce a kinematic regularization operator that penalizes non-physical, instantaneous jumps in the discharge current. This method not only yields a highly accurate, noise-robust emission spectrum but simultaneously extracts the hidden temporal dynamics of the anode current It directly from a single integral attenuation curve.
AB - The accurate determination of emission spectra in nanosecond pulsed x-ray tubes is critical for advanced non-destructive testing, high-speed radiography, and dosimetry calculations. In this paper, we propose a novel computational-experimental approach: the basis-pulse decomposition method with kinematic regularization. Instead of reconstructing the spectrum as a set of independent energy bins, the proposed algorithm shifts the search space into the time domain. The integral spectrum is represented as a temporal superposition of instantaneous physical basis spectra, strictly calculated using the known transient voltage waveform, Kramers' law, and models of anode self-absorption and window filtration. To stabilize the solution, we introduce a kinematic regularization operator that penalizes non-physical, instantaneous jumps in the discharge current. This method not only yields a highly accurate, noise-robust emission spectrum but simultaneously extracts the hidden temporal dynamics of the anode current It directly from a single integral attenuation curve.
UR - https://www.mendeley.com/catalogue/6c322500-bbd7-3772-81c8-2b06c2344a50/
UR - https://www.scopus.com/pages/publications/105055749255
U2 - 10.1063/5.0349535
DO - 10.1063/5.0349535
M3 - Article
C2 - 42969825
VL - 97
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
SN - 0034-6748
IS - 11
M1 - 115201
ER -
ID: 85471022