Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Research › peer-review
Performance of the FCC-ee polarimeter. / Muchnoi, N. Y.
eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. Joint Accelerator Conferences Website (JACoW), 2019. p. 157-164 TUPBB03 (eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders).Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Research › peer-review
}
TY - GEN
T1 - Performance of the FCC-ee polarimeter
AU - Muchnoi, N. Y.
N1 - Publisher Copyright: © eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. All rights reserved.
PY - 2019/2/1
Y1 - 2019/2/1
N2 - Inverse Compton scattering is the classical way to measure the electron beam polarization. Eligibility of the approach at high energy domain has been demonstrated by LEP [1, 2], HERA [3] and SLD [4] experiments. Fast measurement of beam polarization allows to apply the resonant depolarization technique for precise beam energy determination [5, 6]. The distinctive feature of the FCC-ee polarimeter is the registration of scattered electrons along with scattered photons. Polarimeter is designed to measure the transverse polarization of the non-colliding pilot bunch with 1% accuracy every second. Furthermore the same apparatus allows to measure the beam energy, longitudinal beam polarization (if any) and transverse beam positions/sizes at the place of installation.
AB - Inverse Compton scattering is the classical way to measure the electron beam polarization. Eligibility of the approach at high energy domain has been demonstrated by LEP [1, 2], HERA [3] and SLD [4] experiments. Fast measurement of beam polarization allows to apply the resonant depolarization technique for precise beam energy determination [5, 6]. The distinctive feature of the FCC-ee polarimeter is the registration of scattered electrons along with scattered photons. Polarimeter is designed to measure the transverse polarization of the non-colliding pilot bunch with 1% accuracy every second. Furthermore the same apparatus allows to measure the beam energy, longitudinal beam polarization (if any) and transverse beam positions/sizes at the place of installation.
UR - http://www.scopus.com/inward/record.url?scp=85081097548&partnerID=8YFLogxK
U2 - 10.18429/JACoW-eeFACT2018-TUPBB03
DO - 10.18429/JACoW-eeFACT2018-TUPBB03
M3 - Conference contribution
T3 - eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders
SP - 157
EP - 164
BT - eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders
PB - Joint Accelerator Conferences Website (JACoW)
T2 - 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e� Colliders, eeFACT 2018
Y2 - 24 September 2018 through 27 September 2018
ER -