Standard

Neutral beam injection system for the CAT experiment. / Davydenko, Vladimir I.; Deichuli, Petr P.; Ivanov, Alexander A. et al.

In: Plasma and Fusion Research, Vol. 14, No. Specialissue1, 2402024, 01.01.2019.

Research output: Contribution to journalArticlepeer-review

Harvard

Davydenko, VI, Deichuli, PP, Ivanov, AA & Murakhtin, SV 2019, 'Neutral beam injection system for the CAT experiment', Plasma and Fusion Research, vol. 14, no. Specialissue1, 2402024. https://doi.org/10.1585/pfr.14.2402024

APA

Davydenko, V. I., Deichuli, P. P., Ivanov, A. A., & Murakhtin, S. V. (2019). Neutral beam injection system for the CAT experiment. Plasma and Fusion Research, 14(Specialissue1), [2402024]. https://doi.org/10.1585/pfr.14.2402024

Vancouver

Davydenko VI, Deichuli PP, Ivanov AA, Murakhtin SV. Neutral beam injection system for the CAT experiment. Plasma and Fusion Research. 2019 Jan 1;14(Specialissue1):2402024. doi: 10.1585/pfr.14.2402024

Author

Davydenko, Vladimir I. ; Deichuli, Petr P. ; Ivanov, Alexander A. et al. / Neutral beam injection system for the CAT experiment. In: Plasma and Fusion Research. 2019 ; Vol. 14, No. Specialissue1.

BibTeX

@article{e88ef9f748b743aeb50b4edf432e6557,
title = "Neutral beam injection system for the CAT experiment",
abstract = "In the Budker Institute, the CAT (Compact Axisymmtric Toroid) experiment is being prepared for obtaining a plasmoid with high diamagnetism in axially symmetric magnetic field. Reverse of magnetic field in the plasmoid is also possible in this experiment. The experiment is based on injection of powerful focused neutral beams with extremely large neutral power density in the plasma. Two neutral beam injectors with the energy of hydrogen atoms of 15 keV will be used in the experiment. The neutral beam power of each injector is 2MW, pulse duration is 5ms. In the ion source of the injector, plasma emitter is produced by plasma jets from four arc plasma generators. Proton beam with current up to 170A is formed by multi-slit three-electrode ion-optical system with ballistic focusing. Measured angular divergence of the formed beam along the slits is 10 mrad, divergence in the direction across the slits is 35 mrad. The injector is equipped with a neutralizer, bending magnet, residual ion dump, calorimeter, high speed pumping system with titanium arc evaporation.",
keywords = "Axisymmetric magnetic trap, Ion source, Neutral beam injector, PLASMA, ion source, CELL, neutral beam injector, axisymmetric magnetic trap",
author = "Davydenko, {Vladimir I.} and Deichuli, {Petr P.} and Ivanov, {Alexander A.} and Murakhtin, {Sergey V.}",
year = "2019",
month = jan,
day = "1",
doi = "10.1585/pfr.14.2402024",
language = "English",
volume = "14",
journal = "Plasma and Fusion Research",
issn = "1880-6821",
publisher = "The Japan Society of Plasma Science and Nuclear Fusion Research (JSPF)",
number = "Specialissue1",

}

RIS

TY - JOUR

T1 - Neutral beam injection system for the CAT experiment

AU - Davydenko, Vladimir I.

AU - Deichuli, Petr P.

AU - Ivanov, Alexander A.

AU - Murakhtin, Sergey V.

PY - 2019/1/1

Y1 - 2019/1/1

N2 - In the Budker Institute, the CAT (Compact Axisymmtric Toroid) experiment is being prepared for obtaining a plasmoid with high diamagnetism in axially symmetric magnetic field. Reverse of magnetic field in the plasmoid is also possible in this experiment. The experiment is based on injection of powerful focused neutral beams with extremely large neutral power density in the plasma. Two neutral beam injectors with the energy of hydrogen atoms of 15 keV will be used in the experiment. The neutral beam power of each injector is 2MW, pulse duration is 5ms. In the ion source of the injector, plasma emitter is produced by plasma jets from four arc plasma generators. Proton beam with current up to 170A is formed by multi-slit three-electrode ion-optical system with ballistic focusing. Measured angular divergence of the formed beam along the slits is 10 mrad, divergence in the direction across the slits is 35 mrad. The injector is equipped with a neutralizer, bending magnet, residual ion dump, calorimeter, high speed pumping system with titanium arc evaporation.

AB - In the Budker Institute, the CAT (Compact Axisymmtric Toroid) experiment is being prepared for obtaining a plasmoid with high diamagnetism in axially symmetric magnetic field. Reverse of magnetic field in the plasmoid is also possible in this experiment. The experiment is based on injection of powerful focused neutral beams with extremely large neutral power density in the plasma. Two neutral beam injectors with the energy of hydrogen atoms of 15 keV will be used in the experiment. The neutral beam power of each injector is 2MW, pulse duration is 5ms. In the ion source of the injector, plasma emitter is produced by plasma jets from four arc plasma generators. Proton beam with current up to 170A is formed by multi-slit three-electrode ion-optical system with ballistic focusing. Measured angular divergence of the formed beam along the slits is 10 mrad, divergence in the direction across the slits is 35 mrad. The injector is equipped with a neutralizer, bending magnet, residual ion dump, calorimeter, high speed pumping system with titanium arc evaporation.

KW - Axisymmetric magnetic trap

KW - Ion source

KW - Neutral beam injector

KW - PLASMA

KW - ion source

KW - CELL

KW - neutral beam injector

KW - axisymmetric magnetic trap

UR - http://www.scopus.com/inward/record.url?scp=85063632659&partnerID=8YFLogxK

U2 - 10.1585/pfr.14.2402024

DO - 10.1585/pfr.14.2402024

M3 - Article

AN - SCOPUS:85063632659

VL - 14

JO - Plasma and Fusion Research

JF - Plasma and Fusion Research

SN - 1880-6821

IS - Specialissue1

M1 - 2402024

ER -

ID: 19039322