Research output: Contribution to journal › Article › peer-review
Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes. / Shtro, K. S.; Batrakov, A. M.; Ilyin, I. V. et al.
In: Instruments and Experimental Techniques, Vol. 67, No. 2, 04.2024, p. 320-331.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes
AU - Shtro, K. S.
AU - Batrakov, A. M.
AU - Ilyin, I. V.
AU - Okunev, I. N.
AU - Pavlenko, A. V.
AU - Sinyatkin, S. V.
PY - 2024/4
Y1 - 2024/4
N2 - Abstract: The described system is designed to measure the field map of pulse bending magnets of accelerators. As an example, the magnet, which is an element of the particle bypass channel from the booster to the nuclotron of the NICA complex, which is being created at JINR, is chosen. Analyzing the capabilities of various methods in pulsed-field measurements and requirements for measurement errors in bending magnets better than 10–3 have led to the development of a method based on the use of Hall probes. The article substantiates the developed method, describes its capabilities, and the hardware developed for conducting measurements. In the conclusions, results of measurements of pulsed bending magnets of the booster–nuclotron channel are presented and analyzed.
AB - Abstract: The described system is designed to measure the field map of pulse bending magnets of accelerators. As an example, the magnet, which is an element of the particle bypass channel from the booster to the nuclotron of the NICA complex, which is being created at JINR, is chosen. Analyzing the capabilities of various methods in pulsed-field measurements and requirements for measurement errors in bending magnets better than 10–3 have led to the development of a method based on the use of Hall probes. The article substantiates the developed method, describes its capabilities, and the hardware developed for conducting measurements. In the conclusions, results of measurements of pulsed bending magnets of the booster–nuclotron channel are presented and analyzed.
UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85198039453&origin=inward&txGid=d3d07bdf415855df95980ad65d87f84c
UR - https://www.mendeley.com/catalogue/1ba33961-ae8e-33ed-b486-2a0a1eec94cd/
U2 - 10.1134/S0020441224700593
DO - 10.1134/S0020441224700593
M3 - Article
VL - 67
SP - 320
EP - 331
JO - Instruments and Experimental Techniques
JF - Instruments and Experimental Techniques
SN - 0020-4412
IS - 2
ER -
ID: 61057332