Standard

Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes. / Shtro, K. S.; Batrakov, A. M.; Ilyin, I. V. et al.

In: Instruments and Experimental Techniques, Vol. 67, No. 2, 04.2024, p. 320-331.

Research output: Contribution to journalArticlepeer-review

Harvard

Shtro, KS, Batrakov, AM, Ilyin, IV, Okunev, IN, Pavlenko, AV & Sinyatkin, SV 2024, 'Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes', Instruments and Experimental Techniques, vol. 67, no. 2, pp. 320-331. https://doi.org/10.1134/S0020441224700593

APA

Shtro, K. S., Batrakov, A. M., Ilyin, I. V., Okunev, I. N., Pavlenko, A. V., & Sinyatkin, S. V. (2024). Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes. Instruments and Experimental Techniques, 67(2), 320-331. https://doi.org/10.1134/S0020441224700593

Vancouver

Shtro KS, Batrakov AM, Ilyin IV, Okunev IN, Pavlenko AV, Sinyatkin SV. Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes. Instruments and Experimental Techniques. 2024 Apr;67(2):320-331. doi: 10.1134/S0020441224700593

Author

Shtro, K. S. ; Batrakov, A. M. ; Ilyin, I. V. et al. / Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes. In: Instruments and Experimental Techniques. 2024 ; Vol. 67, No. 2. pp. 320-331.

BibTeX

@article{86490aa32c4949df8e11697ea54efb33,
title = "Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes",
abstract = "Abstract: The described system is designed to measure the field map of pulse bending magnets of accelerators. As an example, the magnet, which is an element of the particle bypass channel from the booster to the nuclotron of the NICA complex, which is being created at JINR, is chosen. Analyzing the capabilities of various methods in pulsed-field measurements and requirements for measurement errors in bending magnets better than 10–3 have led to the development of a method based on the use of Hall probes. The article substantiates the developed method, describes its capabilities, and the hardware developed for conducting measurements. In the conclusions, results of measurements of pulsed bending magnets of the booster–nuclotron channel are presented and analyzed.",
author = "Shtro, {K. S.} and Batrakov, {A. M.} and Ilyin, {I. V.} and Okunev, {I. N.} and Pavlenko, {A. V.} and Sinyatkin, {S. V.}",
year = "2024",
month = apr,
doi = "10.1134/S0020441224700593",
language = "English",
volume = "67",
pages = "320--331",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "2",

}

RIS

TY - JOUR

T1 - Measurement of the Field Map in Pulsed Bending Accelerating Magnets Using Hall Probes

AU - Shtro, K. S.

AU - Batrakov, A. M.

AU - Ilyin, I. V.

AU - Okunev, I. N.

AU - Pavlenko, A. V.

AU - Sinyatkin, S. V.

PY - 2024/4

Y1 - 2024/4

N2 - Abstract: The described system is designed to measure the field map of pulse bending magnets of accelerators. As an example, the magnet, which is an element of the particle bypass channel from the booster to the nuclotron of the NICA complex, which is being created at JINR, is chosen. Analyzing the capabilities of various methods in pulsed-field measurements and requirements for measurement errors in bending magnets better than 10–3 have led to the development of a method based on the use of Hall probes. The article substantiates the developed method, describes its capabilities, and the hardware developed for conducting measurements. In the conclusions, results of measurements of pulsed bending magnets of the booster–nuclotron channel are presented and analyzed.

AB - Abstract: The described system is designed to measure the field map of pulse bending magnets of accelerators. As an example, the magnet, which is an element of the particle bypass channel from the booster to the nuclotron of the NICA complex, which is being created at JINR, is chosen. Analyzing the capabilities of various methods in pulsed-field measurements and requirements for measurement errors in bending magnets better than 10–3 have led to the development of a method based on the use of Hall probes. The article substantiates the developed method, describes its capabilities, and the hardware developed for conducting measurements. In the conclusions, results of measurements of pulsed bending magnets of the booster–nuclotron channel are presented and analyzed.

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85198039453&origin=inward&txGid=d3d07bdf415855df95980ad65d87f84c

UR - https://www.mendeley.com/catalogue/1ba33961-ae8e-33ed-b486-2a0a1eec94cd/

U2 - 10.1134/S0020441224700593

DO - 10.1134/S0020441224700593

M3 - Article

VL - 67

SP - 320

EP - 331

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 2

ER -

ID: 61057332