Standard
High precision experiments in the J/ψ, ψ(2S) and τ sector. / Nikolaev, I. B.
 eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. Joint Accelerator Conferences Website (JACoW), 2019. p. 179-181 WEXAA01 (eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders).
Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Research › peer-review
Harvard
Nikolaev, IB 2019, 
High precision experiments in the J/ψ, ψ(2S) and τ sector. in 
eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders., WEXAA01, eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders, Joint Accelerator Conferences Website (JACoW), pp. 179-181, 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e� Colliders, Hong Kong, China, 
24.09.2018. 
https://doi.org/10.18429/JACoW-eeFACT2018-WEXAA01 
			APA
			
			Vancouver
Nikolaev IB. 
High precision experiments in the J/ψ, ψ(2S) and τ sector. In eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. Joint Accelerator Conferences Website (JACoW). 2019. p. 179-181. WEXAA01. (eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders). doi: 10.18429/JACoW-eeFACT2018-WEXAA01
 
				Author
Nikolaev, I. B. / 
High precision experiments in the J/ψ, ψ(2S) and τ sector. eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. Joint Accelerator Conferences Website (JACoW), 2019. pp. 179-181 (eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders).
 
			BibTeX
@inproceedings{a4fe9443129d44b6b5a91f549fcda0c1,
  title     = "High precision experiments in the J/ψ, ψ(2S) and τ sector",
  abstract  = "High precision experiments in charmonium sector require beam energy calibration. VEPP-4M [1] storage ring with energy measurement by resonant depolarization (RD) method provided high precision mass measurement of J/ψ- and ψ(2S)- mesons with KEDR detector with accuracy 2 × 10−6 [2]. This narrow resonances can be used for calibration of energy scale of other accelerators such as BEPC-II or future Super Charm-Tau Factories equipped with Compton backscattering (CBS) energy measurement system.",
  author    = "Nikolaev, {I. B.}",
  note      = "Publisher Copyright: {\textcopyright} eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders. All rights reserved.; 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e� Colliders, eeFACT 2018 ; Conference date: 24-09-2018 Through 27-09-2018",
  year      = "2019",
  month     = feb,
  day       = "1",
  doi       = "10.18429/JACoW-eeFACT2018-WEXAA01",
  language  = "English",
  isbn      = "9783954502165",
  series    = "eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders",
  publisher = "Joint Accelerator Conferences Website (JACoW)",
  pages     = "179--181",
  booktitle = "eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders",
  address   = "Switzerland",
}
RIS
TY  - GEN
T1  - High precision experiments in the J/ψ, ψ(2S) and τ sector
AU  - Nikolaev, I. B.
N1  - Conference code: 62
PY  - 2019/2/1
Y1  - 2019/2/1
N2  - High precision experiments in charmonium sector require beam energy calibration. VEPP-4M [1] storage ring with energy measurement by resonant depolarization (RD) method provided high precision mass measurement of J/ψ- and ψ(2S)- mesons with KEDR detector with accuracy 2 × 10−6 [2]. This narrow resonances can be used for calibration of energy scale of other accelerators such as BEPC-II or future Super Charm-Tau Factories equipped with Compton backscattering (CBS) energy measurement system.
AB  - High precision experiments in charmonium sector require beam energy calibration. VEPP-4M [1] storage ring with energy measurement by resonant depolarization (RD) method provided high precision mass measurement of J/ψ- and ψ(2S)- mesons with KEDR detector with accuracy 2 × 10−6 [2]. This narrow resonances can be used for calibration of energy scale of other accelerators such as BEPC-II or future Super Charm-Tau Factories equipped with Compton backscattering (CBS) energy measurement system.
UR  - http://www.scopus.com/inward/record.url?scp=85081096866&partnerID=8YFLogxK
UR  - https://www.mendeley.com/catalogue/a95433ec-b23e-324d-a577-297f4fdbf325/
U2  - 10.18429/JACoW-eeFACT2018-WEXAA01
DO  - 10.18429/JACoW-eeFACT2018-WEXAA01
M3  - Conference contribution
SN  - 9783954502165
T3  - eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders
SP  - 179
EP  - 181
BT  - eeFACT 2018 - Proceedings of the 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e- Colliders
PB  - Joint Accelerator Conferences Website (JACoW)
T2  - 62nd ICFA Advanced Beam Dynamics Workshop on High Luminosity Circular e+e� Colliders
Y2  - 24 September 2018 through 27 September 2018
ER  -