Standard

Geometric alignment of the SND detector. / Korol, A. A.; Melnikova, N. A.

In: Journal of Physics: Conference Series, Vol. 928, No. 1, 012010, 27.11.2017.

Research output: Contribution to journalArticlepeer-review

Harvard

Korol, AA & Melnikova, NA 2017, 'Geometric alignment of the SND detector', Journal of Physics: Conference Series, vol. 928, no. 1, 012010. https://doi.org/10.1088/1742-6596/928/1/012010

APA

Korol, A. A., & Melnikova, N. A. (2017). Geometric alignment of the SND detector. Journal of Physics: Conference Series, 928(1), [012010]. https://doi.org/10.1088/1742-6596/928/1/012010

Vancouver

Korol AA, Melnikova NA. Geometric alignment of the SND detector. Journal of Physics: Conference Series. 2017 Nov 27;928(1):012010. doi: 10.1088/1742-6596/928/1/012010

Author

Korol, A. A. ; Melnikova, N. A. / Geometric alignment of the SND detector. In: Journal of Physics: Conference Series. 2017 ; Vol. 928, No. 1.

BibTeX

@article{ca6ca1863a484871b74133b3a91931d7,
title = "Geometric alignment of the SND detector",
abstract = "We present the design, implementation and validation of the software procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position by means of a set of parameters. The parameter values are determined by minimizing χ 2 function using the difference between directions reconstructed in these two subdetectors for e + e - → e + e - data events.",
author = "Korol, {A. A.} and Melnikova, {N. A.}",
year = "2017",
month = nov,
day = "27",
doi = "10.1088/1742-6596/928/1/012010",
language = "English",
volume = "928",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Geometric alignment of the SND detector

AU - Korol, A. A.

AU - Melnikova, N. A.

PY - 2017/11/27

Y1 - 2017/11/27

N2 - We present the design, implementation and validation of the software procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position by means of a set of parameters. The parameter values are determined by minimizing χ 2 function using the difference between directions reconstructed in these two subdetectors for e + e - → e + e - data events.

AB - We present the design, implementation and validation of the software procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position by means of a set of parameters. The parameter values are determined by minimizing χ 2 function using the difference between directions reconstructed in these two subdetectors for e + e - → e + e - data events.

UR - http://www.scopus.com/inward/record.url?scp=85039454495&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/928/1/012010

DO - 10.1088/1742-6596/928/1/012010

M3 - Article

AN - SCOPUS:85039454495

VL - 928

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012010

ER -

ID: 9643386