Research output: Contribution to journal › Article › peer-review
Efficiency of non-resonant photon trap for future experiments on neutralisation of negative hydrogen ion beam. / Atlukhanov, Magomedrizy Gadjimuradovich; Burdakov, Alexander Vladimirovich; Popov, Sergey Sergeevich et al.
In: Journal of Plasma Physics, Vol. 92, No. 4, E106, 04.08.2026.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Efficiency of non-resonant photon trap for future experiments on neutralisation of negative hydrogen ion beam
AU - Atlukhanov, Magomedrizy Gadjimuradovich
AU - Burdakov, Alexander Vladimirovich
AU - Popov, Sergey Sergeevich
AU - Trunev, Yuri Alexandrovich
AU - Skovorodin, Dmitry Ivanovich
AU - Kasatov, Alexander Alexandrovich
AU - Shikhovtsev, Igor Vladimirovich
AU - Kurkuchekov, Victor Viktorovich
N1 - Atlukhanov MG, Burdakov AV, Popov SS, et al. Efficiency of non-resonant photon trap for future experiments on neutralisation of negative hydrogen ion beam. Journal of Plasma Physics. 2026;92(4):E106. doi:10.1017/S0022377826102086
PY - 2026/8/4
Y1 - 2026/8/4
N2 - This paper presents experimental investigations of a non-resonant photon trap featuring adiabatic radiation confinement, designed for the photoneutralisation of negative hydrogen (H−/D−) ion beams in fusion plasma injection heating systems. The trap is formed by two monolithic dielectric mirrors with high reflectivity. The study focuses on the methodology and results of measuring the confinement time and integral optical losses. The diagnostic approach is based on analysing the decay rate of radiation within the optical cavity following abrupt interruption of the pump source, utilising wire attenuators for signal reduction. The influence of the laser beam angular divergence on the accumulation efficiency is examined. The obtained data confirm the adiabatic nature of the photon confinement, demonstrate consistency between the measured losses and the specified mirror coating parameters and validate the feasibility of controlling the density of the photon ensemble within the trap. This work confirms the technical feasibility and potential of this approach for the development of high-efficiency photoneutralisation systems.
AB - This paper presents experimental investigations of a non-resonant photon trap featuring adiabatic radiation confinement, designed for the photoneutralisation of negative hydrogen (H−/D−) ion beams in fusion plasma injection heating systems. The trap is formed by two monolithic dielectric mirrors with high reflectivity. The study focuses on the methodology and results of measuring the confinement time and integral optical losses. The diagnostic approach is based on analysing the decay rate of radiation within the optical cavity following abrupt interruption of the pump source, utilising wire attenuators for signal reduction. The influence of the laser beam angular divergence on the accumulation efficiency is examined. The obtained data confirm the adiabatic nature of the photon confinement, demonstrate consistency between the measured losses and the specified mirror coating parameters and validate the feasibility of controlling the density of the photon ensemble within the trap. This work confirms the technical feasibility and potential of this approach for the development of high-efficiency photoneutralisation systems.
KW - fusion plasma
KW - intense particle beams
KW - plasma heating
KW - термоядерная плазма
KW - интенсивные пучки частиц
KW - нагрев плазмы
UR - https://www.mendeley.com/catalogue/be4fb8f4-4c54-388f-bfc1-8cd824cb6b54/
UR - https://www.scopus.com/pages/publications/105046904787
U2 - 10.1017/S0022377826102086
DO - 10.1017/S0022377826102086
M3 - Article
VL - 92
JO - Journal of Plasma Physics
JF - Journal of Plasma Physics
SN - 0022-3778
IS - 4
M1 - E106
ER -
ID: 85319902