Standard

C.M.S. energy calibration in BES-III and VEPP-2000 experiments. / Achasov, M. N.; Muchnoi, N. Yu.

In: Journal of Instrumentation, Vol. 15, No. 7, C07005, 07.2020.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Achasov MN, Muchnoi NY. C.M.S. energy calibration in BES-III and VEPP-2000 experiments. Journal of Instrumentation. 2020 Jul;15(7):C07005. doi: 10.1088/1748-0221/15/07/C07005

Author

BibTeX

@article{f1de848a06a14fb29288430fce771f51,
title = "C.M.S. energy calibration in BES-III and VEPP-2000 experiments",
abstract = "Laser backscattering was implemented as a tool for accurate beam energy measurement at BES-III and VEPP-2000 electron-positron colliders. Here we summarize the experience obtained during these experiments. In fact, this report is the revised and updated version of our previous report on the same topic [1].",
keywords = "Gamma detectors (scintillators, CZT, HPGe, HgI etc), Instrumentation for particle accelerators and storage rings - low energy (linear accelerators, cyclotrons, electrostatic accelerators), Instrumentation for synchrotron radiation accelerators, Solid state detectors, BACKSCATTERED LASER PHOTONS, BEAM ENERGY, GAMMA-RAY, SYSTEM",
author = "Achasov, {M. N.} and Muchnoi, {N. Yu}",
year = "2020",
month = jul,
doi = "10.1088/1748-0221/15/07/C07005",
language = "English",
volume = "15",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "7",

}

RIS

TY - JOUR

T1 - C.M.S. energy calibration in BES-III and VEPP-2000 experiments

AU - Achasov, M. N.

AU - Muchnoi, N. Yu

PY - 2020/7

Y1 - 2020/7

N2 - Laser backscattering was implemented as a tool for accurate beam energy measurement at BES-III and VEPP-2000 electron-positron colliders. Here we summarize the experience obtained during these experiments. In fact, this report is the revised and updated version of our previous report on the same topic [1].

AB - Laser backscattering was implemented as a tool for accurate beam energy measurement at BES-III and VEPP-2000 electron-positron colliders. Here we summarize the experience obtained during these experiments. In fact, this report is the revised and updated version of our previous report on the same topic [1].

KW - Gamma detectors (scintillators, CZT, HPGe, HgI etc)

KW - Instrumentation for particle accelerators and storage rings - low energy (linear accelerators, cyclotrons, electrostatic accelerators)

KW - Instrumentation for synchrotron radiation accelerators

KW - Solid state detectors

KW - BACKSCATTERED LASER PHOTONS

KW - BEAM ENERGY

KW - GAMMA-RAY

KW - SYSTEM

UR - http://www.scopus.com/inward/record.url?scp=85088015327&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/15/07/C07005

DO - 10.1088/1748-0221/15/07/C07005

M3 - Article

AN - SCOPUS:85088015327

VL - 15

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 7

M1 - C07005

ER -

ID: 24813855