Standard

Beam-based mapping of pulsed septum stray field at VEPP-2000 collider. / Shwartz, D.; Koop, I.; Lyalin, M. et al.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 935, 11.08.2019, p. 135-142.

Research output: Contribution to journalArticlepeer-review

Harvard

Shwartz, D, Koop, I, Lyalin, M & Perevedentsev, E 2019, 'Beam-based mapping of pulsed septum stray field at VEPP-2000 collider', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 935, pp. 135-142. https://doi.org/10.1016/j.nima.2019.05.009

APA

Shwartz, D., Koop, I., Lyalin, M., & Perevedentsev, E. (2019). Beam-based mapping of pulsed septum stray field at VEPP-2000 collider. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 935, 135-142. https://doi.org/10.1016/j.nima.2019.05.009

Vancouver

Shwartz D, Koop I, Lyalin M, Perevedentsev E. Beam-based mapping of pulsed septum stray field at VEPP-2000 collider. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 Aug 11;935:135-142. doi: 10.1016/j.nima.2019.05.009

Author

Shwartz, D. ; Koop, I. ; Lyalin, M. et al. / Beam-based mapping of pulsed septum stray field at VEPP-2000 collider. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 ; Vol. 935. pp. 135-142.

BibTeX

@article{c66e3f907e014e10b3b1ffafce840158,
title = "Beam-based mapping of pulsed septum stray field at VEPP-2000 collider",
abstract = "Various beam-based methods are widely used for machine studies and accurate tuning. A response of the beam closed orbit (CO) is routinely used worldwide for alignment of magnetic elements and lattice correction. The paper presents a beam-based field mapping technique applied for measurements of the pulsed septum magnet stray field at the VEPP-2000 electron–positron collider. A relatively slow pulse of a weak leakage field disturbs the CO allowing detecting the field longitudinal integral. While scanning with the transverse coordinate in a wide range one can measure the field map of the localized perturbation at the machine in situ.",
author = "D. Shwartz and I. Koop and M. Lyalin and E. Perevedentsev",
year = "2019",
month = aug,
day = "11",
doi = "10.1016/j.nima.2019.05.009",
language = "English",
volume = "935",
pages = "135--142",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",

}

RIS

TY - JOUR

T1 - Beam-based mapping of pulsed septum stray field at VEPP-2000 collider

AU - Shwartz, D.

AU - Koop, I.

AU - Lyalin, M.

AU - Perevedentsev, E.

PY - 2019/8/11

Y1 - 2019/8/11

N2 - Various beam-based methods are widely used for machine studies and accurate tuning. A response of the beam closed orbit (CO) is routinely used worldwide for alignment of magnetic elements and lattice correction. The paper presents a beam-based field mapping technique applied for measurements of the pulsed septum magnet stray field at the VEPP-2000 electron–positron collider. A relatively slow pulse of a weak leakage field disturbs the CO allowing detecting the field longitudinal integral. While scanning with the transverse coordinate in a wide range one can measure the field map of the localized perturbation at the machine in situ.

AB - Various beam-based methods are widely used for machine studies and accurate tuning. A response of the beam closed orbit (CO) is routinely used worldwide for alignment of magnetic elements and lattice correction. The paper presents a beam-based field mapping technique applied for measurements of the pulsed septum magnet stray field at the VEPP-2000 electron–positron collider. A relatively slow pulse of a weak leakage field disturbs the CO allowing detecting the field longitudinal integral. While scanning with the transverse coordinate in a wide range one can measure the field map of the localized perturbation at the machine in situ.

UR - http://www.scopus.com/inward/record.url?scp=85065716713&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2019.05.009

DO - 10.1016/j.nima.2019.05.009

M3 - Article

AN - SCOPUS:85065716713

VL - 935

SP - 135

EP - 142

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

ER -

ID: 20048717