Research output: Contribution to journal › Article › peer-review
Analytical Control of Impurities and Active Ingredients in a (–)-Isopulegol Derivative with Highly Potent Analgesic Activity. / Lastovka, A. V.; Fedeeva, V. P.; Il’ina, I. V. et al.
In: Pharmaceutical Chemistry Journal, Vol. 54, No. 2, 01.05.2020, p. 190-194.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Analytical Control of Impurities and Active Ingredients in a (–)-Isopulegol Derivative with Highly Potent Analgesic Activity
AU - Lastovka, A. V.
AU - Fedeeva, V. P.
AU - Il’ina, I. V.
AU - Salakhutdinov, N. F.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - An HPLC-UV procedure is proposed for identifying processing impurities and determining the contents of active ingredient in the drug substance of the promising non-narcotic analgesic (2R,4R,4aR,7R,8aR)- 4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol (1). Processing impurities including the starting reagents thiophene-2-carbaldehyde and (–)-isopulegol, a related stereoisomer of 1, and intermediates and dehydration products of 1 could be present as a result of the synthesis and isolation. The developed chromatography conditions could separate possible impurities and analyte 1 with the required resolution. The contents of the studied processing impurities were below the established detection limits of 0.056 μg/mL for thiophene-2-carbaldehyde; 0.32, (–)-isopulegol; 0.22, the stereoisomer; and 0.18, 0.22, and 0.37, for the dehydration products. The working range of concentrations for the procedure was 0.50 – 10 μg/mL. The recovery varied from 98.9 to 101.2% in the accuracy evaluation. The procedure was demonstrated to have sufficient accuracy. The average relative standard deviation in the intraday precision evaluation was 0.7%; in the interday precision assessment, 0.8%, which were below the acceptance criteria of 2.0 and 3.0%, respectively.
AB - An HPLC-UV procedure is proposed for identifying processing impurities and determining the contents of active ingredient in the drug substance of the promising non-narcotic analgesic (2R,4R,4aR,7R,8aR)- 4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol (1). Processing impurities including the starting reagents thiophene-2-carbaldehyde and (–)-isopulegol, a related stereoisomer of 1, and intermediates and dehydration products of 1 could be present as a result of the synthesis and isolation. The developed chromatography conditions could separate possible impurities and analyte 1 with the required resolution. The contents of the studied processing impurities were below the established detection limits of 0.056 μg/mL for thiophene-2-carbaldehyde; 0.32, (–)-isopulegol; 0.22, the stereoisomer; and 0.18, 0.22, and 0.37, for the dehydration products. The working range of concentrations for the procedure was 0.50 – 10 μg/mL. The recovery varied from 98.9 to 101.2% in the accuracy evaluation. The procedure was demonstrated to have sufficient accuracy. The average relative standard deviation in the intraday precision evaluation was 0.7%; in the interday precision assessment, 0.8%, which were below the acceptance criteria of 2.0 and 3.0%, respectively.
KW - (2R,4R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol
KW - drug substance
KW - HPLC-UV
KW - validation
KW - DESIGN
KW - 4aR
KW - (2R
KW - VALIDATION
KW - STRUCTURAL-CHARACTERIZATION
KW - 8aR)-4
KW - IDENTIFICATION
KW - HYDROCHLORIDE
KW - 7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol
KW - 7R
KW - 4R
UR - http://www.scopus.com/inward/record.url?scp=85085180402&partnerID=8YFLogxK
U2 - 10.1007/s11094-020-02176-0
DO - 10.1007/s11094-020-02176-0
M3 - Article
AN - SCOPUS:85085180402
VL - 54
SP - 190
EP - 194
JO - Pharmaceutical Chemistry Journal
JF - Pharmaceutical Chemistry Journal
SN - 0091-150X
IS - 2
ER -
ID: 24396131