Standard

A Precision High Voltage Pulse Divider. / Batrakov, A. M.; Vasilev, M. Yu; Kotov, E. S. et al.

In: Instruments and Experimental Techniques, Vol. 63, No. 2, 01.04.2020, p. 188-198.

Research output: Contribution to journalArticlepeer-review

Harvard

Batrakov, AM, Vasilev, MY, Kotov, ES & Shtro, KS 2020, 'A Precision High Voltage Pulse Divider', Instruments and Experimental Techniques, vol. 63, no. 2, pp. 188-198. https://doi.org/10.1134/S0020441220020074

APA

Batrakov, A. M., Vasilev, M. Y., Kotov, E. S., & Shtro, K. S. (2020). A Precision High Voltage Pulse Divider. Instruments and Experimental Techniques, 63(2), 188-198. https://doi.org/10.1134/S0020441220020074

Vancouver

Batrakov AM, Vasilev MY, Kotov ES, Shtro KS. A Precision High Voltage Pulse Divider. Instruments and Experimental Techniques. 2020 Apr 1;63(2):188-198. doi: 10.1134/S0020441220020074

Author

Batrakov, A. M. ; Vasilev, M. Yu ; Kotov, E. S. et al. / A Precision High Voltage Pulse Divider. In: Instruments and Experimental Techniques. 2020 ; Vol. 63, No. 2. pp. 188-198.

BibTeX

@article{5e6d347f2b1f421cb402fd1294541d6e,
title = "A Precision High Voltage Pulse Divider",
abstract = "A the high-voltage divider for pulsed signals was developed for multichannel DAQ-system of the LIA-20 linear induction accelerator. The divider satisfies a range of requirements: a range of operating voltages up to 30 kV, a 30 MHz bandwidth, accuracy and stability characteristics that are better than 1%, and repeatability of its parameters during mass production. An analysis of various variants of high-voltage dividers is given: passive capacitive dividers and capacitive dividers with active components, as well as resistive, resistive-capacitive, and combined dividers. The configuration selection of the divider circuit with the necessary properties is substantiated based on the analysis.",
author = "Batrakov, {A. M.} and Vasilev, {M. Yu} and Kotov, {E. S.} and Shtro, {K. S.}",
year = "2020",
month = apr,
day = "1",
doi = "10.1134/S0020441220020074",
language = "English",
volume = "63",
pages = "188--198",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "2",

}

RIS

TY - JOUR

T1 - A Precision High Voltage Pulse Divider

AU - Batrakov, A. M.

AU - Vasilev, M. Yu

AU - Kotov, E. S.

AU - Shtro, K. S.

PY - 2020/4/1

Y1 - 2020/4/1

N2 - A the high-voltage divider for pulsed signals was developed for multichannel DAQ-system of the LIA-20 linear induction accelerator. The divider satisfies a range of requirements: a range of operating voltages up to 30 kV, a 30 MHz bandwidth, accuracy and stability characteristics that are better than 1%, and repeatability of its parameters during mass production. An analysis of various variants of high-voltage dividers is given: passive capacitive dividers and capacitive dividers with active components, as well as resistive, resistive-capacitive, and combined dividers. The configuration selection of the divider circuit with the necessary properties is substantiated based on the analysis.

AB - A the high-voltage divider for pulsed signals was developed for multichannel DAQ-system of the LIA-20 linear induction accelerator. The divider satisfies a range of requirements: a range of operating voltages up to 30 kV, a 30 MHz bandwidth, accuracy and stability characteristics that are better than 1%, and repeatability of its parameters during mass production. An analysis of various variants of high-voltage dividers is given: passive capacitive dividers and capacitive dividers with active components, as well as resistive, resistive-capacitive, and combined dividers. The configuration selection of the divider circuit with the necessary properties is substantiated based on the analysis.

UR - http://www.scopus.com/inward/record.url?scp=85083169054&partnerID=8YFLogxK

U2 - 10.1134/S0020441220020074

DO - 10.1134/S0020441220020074

M3 - Article

AN - SCOPUS:85083169054

VL - 63

SP - 188

EP - 198

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 2

ER -